1. Diesel Engine Exhaust Removal—Training School
Application: Training school operated up to 6 diesel trucks and 3 individual diesel engines simultaneously inside a training room. High smoke loads required source ventilation of airborne contaminants. Direct connection of nozzles to tailpipes isolated operator breathing zones and allowed for engine operation for training purposes.
Filtration Equipment: Twelve Plymovent Hose Drops, 6” Diameter Size with Masterduct MC-HT850, 850 Degree Temperature Hose; One Plymovent TEV-768-60 15 hp BI Blower with Non-Sparking Wheel
Location: Colorado
Type of Dust/Smoke: Diesel engine exhaust
CFM/Static Pressure: 7000 cfm @ 7” s.p.
Dust/Smoke Load: Heavy—Up to 10 engines operating simultaneously